Skip to the content
Jansen GmbH Gebäudetechnik
Outdoor heat pump unit beside the stone facade of a house
Outdoor unit on a pale house wall against a blue sky

Heat pumps for Heinsberg

Heat that runs in a circle Heat pumps in Heinsberg

A heat pump burns nothing. It takes heat from outside, lifts it to the temperature your house needs, hands it to the heating circuits and starts again. We plan the loop, site the unit and connect it, hydraulically and electrically.

  • 01 Take up
  • 02 Compress
  • 03 Hand over

The loop

Four stations, and the circle closes

The path the heat takes is the same in every system. What differs is the house it goes into.

  1. 01

    Take up

    A fan draws outside air across the evaporator. The refrigerant inside it boils at low temperatures and takes up the warmth of the air as it does.

  2. 02

    Compress

    The compressor squeezes the vapour together. Pressure rises, and with the pressure the temperature rises far enough to be useful for heating.

  3. 03

    Hand over

    In the condenser the hot refrigerant gives its heat to the heating water. From there it runs into underfloor circuits, radiators and the hot water cylinder.

  4. 04

    Expand

    The expansion valve lowers the pressure again. The refrigerant cools, turns back to liquid and is ready to take up heat at the first station once more.

The loop runs with no fuel, no delivery and no store. What it needs is electricity for the compressor and a house that can take the heat.

Existing houses

What that means for a house that already stands in Heinsberg

A new build is easy for a heat pump. The interesting houses are the ones already there. Three points decide it, and we look at all three on site.

The heating surface decides

The lower the flow temperature may stay, the calmer the system works. Large surfaces help: underfloor heating, wall heating, generously sized radiators. Where the surfaces are small we go room by room through what can be swapped and what can stay.

The power has to reach it

Compressor, controls and immersion heater hang on your electrical installation. The meter position, the supply cable, the protection and the notification to the network operator belong to the same job as the hydraulics for us. Managing director Lennard Jansen holds the German qualification Elektrotechnikermeister (erworben in Deutschland).

Hot water is a loop of its own

Drinking water needs different temperatures from heating water. Whether a cylinder, a fresh water station or the existing system is the better answer is settled during the site visit, before anything is ordered.

What we do

What we take on at your installation

From the first survey to the day you work the controls yourself.

  1. 01

    Site visit and survey

    We look at the house, the heating, the meter position and the possible siting, and write down what we found.

  2. 02

    Sizing and planning

    Heat load, hydraulics, siting and pipe routes are planned before the first part is ordered.

  3. 03

    Siting outdoors

    A base or a bracket, decoupling against structure borne vibration, condensate drainage and a position that suits your plot.

  4. 04

    Hydraulic connection

    Connection to cylinder, manifold and heating circuits, then filling, venting and the hydraulic balance.

  5. 05

    Electrical connection

    Supply cable, protection, meter position and controls, with the paperwork for the network operator.

  6. 06

    Commissioning and handover

    We start the system, set the heating curve and show you in your own time what you can change yourself.

Enquiry

A call back or a site visit, whichever suits you

Write briefly which house this is about and what heats it today. We will get back to you and say honestly what is worth looking at.

Telephone
+49 2454 938644
Email
info@jansen-elektro.de
Address
Geilenkirchener Straße 65 a, 52538 Gangelt
This page covers
Heinsberg, Kreis Heinsberg

Name, telephone and message are required. The email address is up to you.

Installations

Outdoor units at houses

Four photographs of how an outdoor unit stands at a house: in the yard, at the base, under the eaves, on the wall.

Site visit

The visit comes before the quotation

From a distance nobody can say whether a heat pump suits your house. We come round, look at the heating, the heating surfaces and the meter position, and walk through the rooms with you.

The quotation is built on that visit: what we saw, what we propose and what belongs to it. If a heat pump is not a good fit for your house, we say so openly.

Area

Heinsberg and its districts

The firm sits in Gangelt, in the district of Heinsberg. This page is for Heinsberg and the places that belong to it.

  • Heinsberg
  • Oberbruch
  • Dremmen
  • Kirchhoven
  • Karken
  • Randerath
  • Horst
  • Unterbruch
  • Waldenrath
  • Porselen
  • Lieck
  • Grebben
  • Schafhausen
  • Uetterath
  • Kempen
  • Laffeld
  • Aphoven
  • Schleiden

You live just outside? Ask us, and we will tell you whether we can come.

Questions

Asked and answered

The six questions we hear most often in Heinsberg.

The firm

Who puts the system in

Jansen GmbH Gebäudetechnik sits at Geilenkirchener Straße 65 a in Gangelt, in the district of Heinsberg. The managing director is Lennard Jansen.

Because heating and electrical work sit under one roof here, there is no seam at the heat pump where two firms wait for each other.

Firm
Jansen GmbH Gebäudetechnik
Managing director
Lennard Jansen
Professional title
Elektrotechnikermeister (erworben in Deutschland)
Address
Geilenkirchener Straße 65 a, 52538 Gangelt
Supervisory authority
Handwerkskammer Aachen, Sandkaulbach 17-21, 52062 Aachen
Telephone
+49 2454 938644

The circle closes at your house

A call, or three lines in the form, is enough for us to come and look at your house.

Call Enquire